QSZB-12 pre installed European style substation
QSZB-12 pre installed European style substation
QSZB-12 pre installed European style substation
QSZB-12 pre installed European style substation
QSZB-12 pre installed European style substation
QSZB-12 pre installed European style substation
QSZB-12 pre installed European style substation
+
  • QSZB-12 pre installed European style substation
  • QSZB-12 pre installed European style substation
  • QSZB-12 pre installed European style substation
  • QSZB-12 pre installed European style substation
  • QSZB-12 pre installed European style substation
  • QSZB-12 pre installed European style substation
  • QSZB-12 pre installed European style substation

QSZB-12 pre installed European style substation

Widely used for urban power grid renovation, residential communities, high-rise buildings, industrial and mining, hotels, shopping malls, airports, railways, oil fields, docks, highways, and temporary electricity facilities indoors

Product Description

Functions and Features 

1. High voltage switchgear, transformers, and low-voltage switchgear are integrated, with strong completeness; 

2. Perfect high and low voltage protection, safe and reliable operation, and simple maintenance; 

3. Small land occupation, low investment, short production cycle, and convenient movement; 

4. Flexible and diverse wiring schemes; 

5. Unique Structure: A unique honeycomb structure with a double layer (composite plate) outer shell that is sturdy, insulated and ventilated, aesthetically pleasing, and has a high level of protection. The outer shell materials include stainless steel alloy, aluminum, gold, and cold milk plate color steel plate; 

6. Various types: universal, villa, compact, and other styles; 

7. The high-voltage ring network cabinet can be equipped with network automation terminals (FTUs) to achieve reliable detection of short circuits and single-phase ground faults, with the "four" function, facilitating the upgrading of distribution network automation 

Functions and Features 

Widely used for urban power grid renovation, residential communities, high-rise buildings, industrial and mining, hotels, shopping malls, airports, railways, oil fields, docks, highways, and temporary electricity facilities indoors outfield. 

Normal usage conditions 

1. The altitude shall not exceed 1000m; 

2. Environmental temperature: -25 ° C~+40C; 

3. Relative humidity: The daily average value shall not exceed 95%, and the monthly average value shall not exceed 90%: 

4. Installation site: A place without fire, explosion hazard, conductive dust, chemical corrosive gas, and severe vibration. If the above conditions are exceeded, the user can negotiate with our company

Main technical parameters

Box Transformer Theme Parameters

NameUnitHigh Voltage UnitTransformerLow Voltage Unit
Rated VoltagekV1212/0.40.4
Rated CapacitykVA 30-1600 
Rated CurrentA630 43~2500
Rated Breaking CurrentkA50 15~63
Rated Short-time Withstand CurrentkA/s20/3  
Rated Peak Withstand CurrentkA (Peak)50 30/1
Rated Making CurrentkA50 63
Power Frequency Withstand VoltagekV/min

Phase-to-ground & Phase-to-phase 42/1

 

Isolation Break 48/1

 

10kV Cable DC Withstand Voltage (Phase-to-ground) 25/15

35/12.5/1
Lightning Impulse Withstand VoltagekV (Peak)

Phase-to-ground & Phase-to-phase 75

 

Isolation Break 85

75 
Cabinet Protection Class IP33  
Noise LeveldB ≤65 

The transformer is selected as S11-M fully sealed transformer and SC9 dry-type transformer. The transformer capacity is as follows: 30, 50, 80, 100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600kVA

Parameters of HXGN-12 (F.L) ring main unit

NameUnitLoad SwitchCombined Electrical Appliance
Rated VoltagekV1212
Rated CurrentA630125
Rated FrequencyHz5050
Rated Insulation Level (1min Power Frequency Withstand Voltage: Vacuum Break, Phase-to-Ground Isolation Terminal)kV42/48-
Rated Insulation Level (Lightning Impulse Withstand Voltage: Vacuum Break, Phase-to-Ground Isolation Terminal)kV75/85-
Rated Short-time Withstand CurrentkA/s20/3-
Rated Peak Withstand CurrentkA50-
Rated Short-circuit Breaking CurrentkA-31.5~50
Rated Transfer CurrentA-1000~315
Protection Class--IP3X

Technical parameters of high-voltage fuses

Model (UK)Domestic ModelRated Voltage (kV)Rated Current (A)Breaking Current (A)Fuse Rated Current (A)
SDL□JXRNT-12124031.56.3, 10, 16, 20, 25, 31.5, 40
SFL□JXRNT-121210031.550, 63, 71, 80, 100
SKL□JXRNT-121212531.5125

Parameters of current transformer

ModelRated Voltage (kV)Rated Current RatioAccuracy ClassRated Secondary Load (cosφ=0.8, VA)10% MultiplierThermal Stability MultiplierDynamic Stability Multiplier
LZZBJ9-10(Q)125~1000/50.5S10/75~90190~225
0.510, 15/
10P1515, 2015
0.2S10/
0.210, 15/

Voltage Transformer Parameters

ModelRated Voltage (V)Rated Capacity (VA)Maximum Capacity (VA)
JDZ-10QPrimary CoilSecondary Coil0.2 Class0.5 Class1 Class500
100001003080150

The low-voltage circuit breaker switch adopts DW17, DW45, CW1, etc., and the branch switch selects TM3Q, CM1, DZ20Y, etc.:

视频标题

Factory

Factory equipment
Factory equipment
Factory equipment
Factory equipment
Factory equipment
Factory equipment
Factory equipment
Factory equipment
Factory equipment
Factory equipment
Factory equipment
Factory equipment

YOU MAY ALSO LIKE

Product Consultation

Our staff will contact you within 24 hours (weekdays)

* Note: Please be sure to fill in the information accurately and keep the communication open. We will get in touch with you as soon as possible

Leave Your Message Here.

*Note: Please make sure to fill in the information accurately and maintain smooth communication. We will contact you as soon as possible